From 1def289bb9555a52c1c2fe5da5d20c635b8b46de Mon Sep 17 00:00:00 2001 From: Jaime van Kessel Date: Thu, 3 Oct 2019 09:51:45 +0200 Subject: [PATCH] Fix crash when importing profile that has different quality_definition CURA-6847 --- cura/Settings/CuraContainerRegistry.py | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/cura/Settings/CuraContainerRegistry.py b/cura/Settings/CuraContainerRegistry.py index 84b714fdcf..557246ab1b 100644 --- a/cura/Settings/CuraContainerRegistry.py +++ b/cura/Settings/CuraContainerRegistry.py @@ -238,7 +238,7 @@ class CuraContainerRegistry(ContainerRegistry): # Get the expected machine definition. # i.e.: We expect gcode for a UM2 Extended to be defined as normal UM2 gcode... - profile_definition = container_tree.machines[machine_definition.getId()].quality_definition + profile_definition = machine_definition.getMetaDataEntry("quality_definition", "") expected_machine_definition = container_tree.machines[global_stack.definition.getId()].quality_definition # And check if the profile_definition matches either one (showing error if not):