From 7219d84b913d094d3d91aff9862891eece053e24 Mon Sep 17 00:00:00 2001 From: Jack Ha Date: Mon, 20 Nov 2017 13:01:09 +0100 Subject: [PATCH] CURA-4104 added settings for flow rate compensated extrusion --- resources/definitions/fdmprinter.def.json | 30 +++++++++++++++++++++++ 1 file changed, 30 insertions(+) diff --git a/resources/definitions/fdmprinter.def.json b/resources/definitions/fdmprinter.def.json index 0fedc4accc..b7f5bc8352 100644 --- a/resources/definitions/fdmprinter.def.json +++ b/resources/definitions/fdmprinter.def.json @@ -5589,6 +5589,36 @@ } } }, + "flow_rate_max_extrusion_offset": + { + "label": "Flow rate compensation max extrusion offset", + "description": "The maximum distance in mm to compensate for pressure in the bowden tube.", + "unit": "mm", + "type": "float", + "minimum_value": "0", + "maximum_value_warning": "10", + "default_value": 0, + "value": "0", + "enabled": true, + "settable_per_mesh": false, + "settable_per_extruder": false, + "settable_per_meshgroup": false + }, + "flow_rate_extrusion_offset_factor": + { + "label": "Flow rate compensation factor", + "description": "The multiplication factor for the flow rate -> distance translation.", + "unit": "%", + "type": "float", + "minimum_value": "0", + "maximum_value_warning": "100", + "default_value": 100, + "value": "100", + "enabled": true, + "settable_per_mesh": false, + "settable_per_extruder": false, + "settable_per_meshgroup": false + }, "wireframe_enabled": { "label": "Wire Printing",