From c2c61c4331f3861225d0db5790ca1af30002c616 Mon Sep 17 00:00:00 2001 From: Ghostkeeper Date: Mon, 13 Feb 2017 09:35:09 +0100 Subject: [PATCH] Improve condition for extruder name fallback In effect this has no change. But semantically it is better: If there are no extruders or the extruders have no name, use 'hotend'. Otherwise use the available name. It has nothing to do with the amount of extruders. Contributes to issue CURA-3161. --- resources/qml/PrintMonitor.qml | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/resources/qml/PrintMonitor.qml b/resources/qml/PrintMonitor.qml index 43f771296a..9865f94232 100644 --- a/resources/qml/PrintMonitor.qml +++ b/resources/qml/PrintMonitor.qml @@ -91,7 +91,7 @@ Column Label //Extruder name. { - text: (extrudersRepeater.count > 1 && extrudersModel.getItem(index).name != null) ? extrudersModel.getItem(index).name : catalog.i18nc("@label", "Hotend") + text: (extrudersModel.getItem(index) != null && extrudersModel.getItem(index).name != null) ? extrudersModel.getItem(index).name : catalog.i18nc("@label", "Hotend") color: UM.Theme.getColor("text") font: UM.Theme.getFont("default") anchors.left: parent.left