19 Commits

Author SHA1 Message Date
Remco Burema
c64dcb785c Remove 'support_interface_skip_height' setting.
Was used for run-time efficiency, but it wasn't really ever set beyond one layer-height, which made it rather useless.

frontend part of CURA-11157 -- needed version upgrader as well, since it's the first alteration
2024-01-10 08:55:56 +01:00
Thomas Rahm
536c95555e Suggested profile changes: Ensure minimum support area is 0 for tree support to avoid 'No trees generated' bug report. Removed extra z heightfor Tree support as this should no longer be required with the new implementation 2023-03-29 06:50:30 +02:00
Remco Burema
cf922295db Try before the beta. After it's too late.
A lot was changed in support. The short of it is that we now think towers should be on by default, but aren't _completely_ certain about it. It makes more sense to do make this change before the beta rather than just before stable, so we have a chance to revert should it prove disastrous.
2023-02-21 15:43:12 +01:00
jspijker
53d8e0c730 Applied printer-linter format
To make sure we have uniform diffs with our PR's
2022-12-30 22:05:41 +01:00
Jaime van Kessel
2c331604e8
Clean up a lot of duplicate settings from machine profiles
These were errors that were copy pasted from other definitions. So leaving them as is would
continue to decrease the quality of third party profiles.
2022-09-06 11:39:08 +02:00
Jaime van Kessel
3101f2aea4 Remove filter_out_tiny_gaps from definitions
This setting doesn't exist anymore.
2022-06-17 15:57:40 +02:00
Konstantinos Karmas
0e7553e95e Merge branch 'master' into libArachne_rebased 2021-08-03 13:09:17 +02:00
Luke Harrison
918d1f188b
Biqu bx definition (#10086)
* Added prelim support for the BX

* Revert "Added prelim support for the BX"

This reverts commit 923fbdbbb617d000663f04d08d468ed0c560517c.

* Added prelim support for the BX

* Revert "Added prelim support for the BX"

This reverts commit 923fbdbbb617d000663f04d08d468ed0c560517c.

* Added BIQU BX printer def

* Updated the platform name.

* Minor update to the start code. Ready for merge.
2021-07-19 15:57:30 +02:00
Ghostkeeper
611208368c
Merge branch 'master' into libArachne_rebased
Conflicts:
	cura/CuraApplication.py: Setting version
	fdmprinter and fdmextruder: Setting version
	intents, qualities and variants: Setting version
	Changelog: 4.9.1 was added, should be below Arachne changes
2021-06-16 18:04:54 +02:00
Ghostkeeper
dc09465afe
Standardise capitalisation of printer names
Some contributors seem to have a shift key stuck here or there. Many 'stylised' capitalisations weren't reflected even on the manufacturer's websites, or were also stylising words like 'pro' and 'dual' or even actual chemical names like 'nylon'. Normalising the caps makes it more fair for everyone, since all of these are written in the same font.

As discussed with the Cura team.
2021-06-11 13:49:35 +02:00
Remco Burema
db33f67666
Partial revert: Don't remove 'Print Thin Walls'.
It still makes sense, even in a libArachne/Variable Line Width sense.

CURA-7148
2020-12-10 12:49:00 +01:00
Remco Burema
77c39247f9
... also of course delete them from definitions.
Context: Print Thin Walls and Fill Perimeter Gaps are old settings that aren't needed any more since we switched to libArachne (Varianble Line Widths).

CURA-7148
2020-12-09 21:20:08 +01:00
Ghostkeeper
66a0b4b5a5
Merge branch 'master' into libArachne_rebased 2020-12-08 09:28:40 +01:00
Or Bin
590e46cef3 Fixed typo: positionning -> positioning 2020-11-28 22:45:58 +02:00
Jaime van Kessel
c70fe3c107
Remove a deleted setting from various profiles 2020-11-23 17:26:24 +01:00
Ghostkeeper
ef7cfd846b
Change maximum resolution from 0.05mm to 0.25mm
This was found to be better in https://github.com/Ultimaker/Cura/issues/8321 due to changes to the simplification function.

Other printers are assumed to have a similar effect, or have their original value copied from Creality printers.
2020-11-03 11:48:07 +01:00
Ghostkeeper
55f0c10f94
Upgrade usage of support_tree_enabled
This setting no longer exists.

Contributes to issue CURA-7752.
2020-10-05 17:59:57 +02:00
Ghostkeeper
9b5005fc90
Fix Biqu definition files
There were a number of problems with it:
* There were duplicate JSON keys. One of the duplicates gets ignored then according to the JSON implementation in Python.
* There were some 'value' properties that contained undefined variables since the setting type was a string and the value is a string containing a Python expression that should result in a string, not a plain string.
* There was one instance in which a 'default_value' property contained a formula.

Contributes to issue CURA-7752.
2020-10-05 13:47:24 +02:00
Luke Harrison
ecf32a261e
Added BIQU machine base files as well as BIQU B1 machine files. (#8276)
* Added BIQU machine base files as well as BIQU B1 machine files.

* Fixed a variants settings version error.

* Updated base def by removing excluded materials and changing the pref to pla175

* Fixed the machine name value which should only take a default value and not also a value.

* Increased the max extruder feedrate to allow the default retraction speed.

* Removed comments from the quality profiles. Removed author from variants. Adjusted materials in quality profiles to refer to the 175 profiles directly.

* Enabled coasting by default in the B1 profile and increased the width of infill for the base profile.

* Updated all quality and variants configs to use settings version 16 in anticipation of release 4.8

* Final tweaks to B1 start gcode

* Added an ABL version of the B1 with tweaked start codes.
2020-09-30 17:00:10 +02:00