Lipu Fei
39158a643c
Revert "Ignore per-meshgroup settings in per object stack"
...
CURA-5767
This reverts commit 54afa799c54bf3727481241e5e5f45dffb7e3442.
2018-10-30 07:33:55 +01:00
Lipu Fei
54afa799c5
Ignore per-meshgroup settings in per object stack
...
CURA-5767
2018-10-29 15:05:49 +01:00
Lipu Fei
248bf0f61e
Merge remote-tracking branch 'origin/3.6' into CURA-5767_disable_per_meshgroup_settings_for_one_at_a_time
2018-10-29 14:32:44 +01:00
Lipu Fei
1623f66c93
Merge pull request #4656 from fieldOfView/fix_network_camera_memory_leak
...
[3.6] Fix memory leak in print monitor
2018-10-29 14:12:31 +01:00
Lipu Fei
02681a5700
Change camera URL to non-optional QUrl
...
Otherwise pyqt property will complain when it tries to convert a None to
a QUrl.
2018-10-29 13:25:23 +01:00
fieldOfView
e0d6bac37d
Fix remaining references to NetworkCamera and OutputDevice.activeCamera
2018-10-29 11:18:54 +01:00
fieldOfView
c187b6a25c
Replace NetworkCamera with NetworkMJPGImage
2018-10-29 11:18:39 +01:00
Lipu Fei
2223ff14f7
Fix extruder index for material diameter box in MachineSettings dialog
...
CURA-5857
2018-10-29 10:40:25 +01:00
Remco Burema
5133b6300a
Merge pull request #4650 from Ultimaker/CURA-5857_fix_machine_settings_set_diameter
...
[3.6] [CURA-5857] Fix setting extruder material diameter in Machine Settings dialog
2018-10-26 17:35:50 +02:00
Remco Burema
de680f4aac
Merge pull request #4669 from Ultimaker/CURA-5821_fix_camera_memory_leak
...
Cura 5821 fix camera memory leak
2018-10-26 15:00:03 +02:00
Remco Burema
24f9804f03
Disable per-meshgroup settings in the per-mesh settings when in one-at-a-time mode.
...
[CURA-5767]
The backend can't handle per mesh-group settings (as opposed to per mesh settings)
when sequence was in one-at-a-time mode. The problem is that the extruder train is
in between the per-meshgroup-settings (child-of) and per-mesh-settings (parent-of).
For any per-mesh-group settings, the possibility exists that they'll be overridden
by settings we always set (and that need to be set) per extruder. Changing this
would require the engine-architecture to change, and _all_ settings would need to
be thouroughly retested. As this was a too extensive change, it was decied just to
disable the per-meshgroup settings when printing one-at-a-time (too).
The issue was originally reported as:
'"Printing Temperature Initial layer" setting per mode does not work'
2018-10-26 11:01:46 +02:00
Ian Paschal
94d48101d9
Use different lengths for loading skeleton and printer name
...
Contributes to CL-1119
2018-10-25 16:45:49 +02:00
Diego Prado Gesto
f1d94d921c
The MachineManager doesn't have the extruder stacks but the active
...
machine does, so use it when setting the compatible material diameter to
the current extruder.
Contributes to CURA-5857.
2018-10-25 16:27:16 +02:00
Diego Prado Gesto
197bf057cc
Merge branch '3.6' into CURA-5857_fix_machine_settings_set_diameter
2018-10-25 15:57:26 +02:00
Lipu Fei
6fd7b49937
Fix setting extruder material diameter in Machine Settings dialog
...
CURA-5857
It should update the value of the selected Extruder TAB, not the active
extruder on the printer.
2018-10-25 15:11:04 +02:00
Lipu Fei
31bdeb8b73
Merge remote-tracking branch 'origin/3.6' into CURA-5821_fix_camera_memory_leak
2018-10-25 14:53:42 +02:00
Ghostkeeper
c7b146c9fc
Don't make retract distances negative
...
People are reporting that the retraction is reversed. We can't test it since we have no firmware that supports the command at all. So we'll just not make the retract distance negative. That seems more logical anyway if you read the documentation of M600 to the letter.
Fixes #4249 .
2018-10-25 13:54:00 +02:00
Ian Paschal
1a67660196
Hotfix: Show printer selection
2018-10-25 10:54:59 +02:00
Ghostkeeper
12eb43b8fd
Merge branch 'CURA-5769_gcode_retraction'
2018-10-24 16:14:05 +02:00
Lipu Fei
9d07409cce
WIP: Use CameraView for UM camera feeds
...
CURA-5821
The original implementation that refreshes a QImage seems to cause
memory overflow on MacOSX and Windows. This is a different
implementation. It doesn't cause memory overflow, but it does consume a
lot of CPU power.
2018-10-24 16:00:22 +02:00
Ghostkeeper
9b74dfd5ec
Correct typo
...
intented -> intended
2018-10-24 15:54:45 +02:00
Ian Paschal
be5c1c8596
Merge pull request #4436 from Ultimaker/clean_print_job_info_block
...
CL-897, CL-1051, CL-1111 Cura 3.6 Monitor Tab
2018-10-24 12:29:46 +02:00
Ian Paschal
d077dcc851
Fix printer card skeleton colors
...
Contributes to CL-1051
2018-10-24 11:13:38 +02:00
Ian Paschal
8662e1a125
Fix override dialog box
...
Contributes to CL-897
2018-10-24 11:13:12 +02:00
Ian Paschal
a247fe204f
Fix print job context menu height
...
Contributes to CL-897, CL-1051, CL-1111
2018-10-23 16:27:45 +02:00
Ian Paschal
0045559d01
QML Clean-up
...
Contributes to CL-897, CL-1051, CL-1111
2018-10-23 15:45:44 +02:00
Ian Paschal
f9545a339d
QML Clean-up
...
Contributes to CL-897, CL-1051, CL-1111
2018-10-23 15:41:56 +02:00
Ian Paschal
1bd488dd6c
Remove comments
...
Contributes to CL-897
2018-10-23 15:25:42 +02:00
Remco Burema
3dab627670
Merge pull request #4618 from Ultimaker/CURA-5834_fix_material_model_update
...
CURA-5834 Fix material model update
2018-10-23 14:54:34 +02:00
Lipu Fei
1675ad4ba5
Merge pull request #4487 from fieldOfView/fix_marlin_press_to_resume
...
Fix "press to resume" message after heating bed when usb is connected
2018-10-23 10:27:40 +02:00
Diego Prado Gesto
94ef0b92fe
Fix typo in the getCompatibleMaterialDiameter function.
...
Contributes to CURA-5834.
2018-10-23 10:25:13 +02:00
Ian Paschal
9a16d45be5
Round divisions
...
Contributes to CL-1051, CL-897, CL-1111
2018-10-22 16:02:55 +02:00
Ian Paschal
34abc48a1a
Remove binding loops
...
Contributes to CL-1051
2018-10-22 15:31:38 +02:00
Lipu Fei
ea9aa2c777
Add doc for using setCompatibleMaterialDiameter() in QML
...
CURA-5834
2018-10-22 10:56:11 +02:00
Ian Paschal
817899686a
Dark mode theme improvements
...
Contributes to CL-1111
2018-10-19 16:23:16 +02:00
fieldOfView
68c3023a46
Make sure firmware name is only requested once
2018-10-19 14:38:25 +02:00
fieldOfView
71d365c0c6
Fix case where Cura and the firmware could be waiting for eachother
2018-10-19 14:37:20 +02:00
Lipu Fei
97e6354c13
Fix material update upon extruder-compatible diameter change
...
CURA-5834
Material models and the material container on an extruder need to be
updated when the extruder's compatible diameter gets changes.
2018-10-19 13:48:52 +02:00
Aleksei S
22db3cb32b
Show retraction for G92 command
...
CURA-5769
2018-10-19 13:18:42 +02:00
Lipu Fei
ea10d5e608
Rename to comptabileMaterialDiameter
...
CURA-5834
This property returns the material diameter an extruder is compatible
with, so this makes it more clear.
2018-10-19 11:36:12 +02:00
Ghostkeeper
2eb9b111fc
Fix changing flow rate in dual extrusion
...
This potentially set the flow rate to -1, since it was changing the flow rate to the old['flowrateTwo'] which was left at -1 since initialisation because it didn't update here.
2018-10-19 09:55:23 +02:00
Ghostkeeper
9aa7b76dbe
Update change log with 3.5.1 changes
...
Too little, too late. But at least you'll be able to look back on it.
2018-10-19 07:55:39 +02:00
fieldOfView
777470db7f
Don't force sending M105 requests without OK
...
This prevents serial buffer overflow on the printer.
2018-10-18 15:47:25 +02:00
fieldOfView
f4c88aff0f
Merge branch 'master' into fix_marlin_press_to_resume
2018-10-18 15:35:57 +02:00
Ian Paschal
1ad008f45c
Style improvements
...
Contributes to CL-897 and CL-1051
2018-10-17 16:32:30 +02:00
Ian Paschal
6f33c4410c
Review tweaks
...
Contributes to CL-897 and CL-1051
2018-10-17 14:39:42 +02:00
Ian Paschal
2dcfc049ba
Remove skeleton loading after print jobs received
...
Contributes to CL-1051
2018-10-17 14:28:17 +02:00
alekseisasin
a7be605b9d
Typing error in CI CURA-5769
2018-10-17 09:50:22 +02:00
Aleksei S
20fa7f4dd8
Display retractions lines for the loaded Gcode files
...
CURA-5769
2018-10-16 16:47:05 +02:00
Ian Paschal
b99bc06d1c
Clean up more errors
...
Contributes to CL-1051
2018-10-16 09:34:50 +02:00