746 Commits

Author SHA1 Message Date
ChrisTerBeke
8cfaa44580 Fix resolving global stack definition when switching variant - CURA-4620 2017-11-27 16:40:23 +01:00
Jaime van Kessel
083eee2e9d Merge branch 'master' of github.com:Ultimaker/Cura into network_rewrite 2017-11-27 13:43:39 +01:00
ChrisTerBeke
8082c092e5 Fix setting extruder definition in user changes container 2017-11-27 09:54:10 +01:00
Aleksei S
bb2be70dac Finds candidate quality profile for fdmextruder
CURA-4620
2017-11-25 02:25:36 +01:00
Jaime van Kessel
219e285b20 Merge branch 'master' of github.com:Ultimaker/Cura into network_rewrite 2017-11-24 09:23:21 +01:00
Jack Ha
3b5ed70113 CURA-4602 Fixed active custom profile selected check 2017-11-22 16:15:06 +01:00
ChrisTerBeke
532cfd8404 Fix showing correct quality changes in dropdown list after upgrading - CURA-4482 2017-11-22 10:48:21 +01:00
Lipu Fei
aeb478bb4b Should only show Keep/Discard dialog when it's needed
CURA-4599
2017-11-22 09:32:17 +01:00
Lipu Fei
31c859b3d7 Show Keep/Discard dialog after the containers have been changed
CURA-4599

Or the default values will reflect those before the switch.
2017-11-22 09:18:20 +01:00
Jaime van Kessel
0f78b05802 Connection states changes are now tied into the UI again
CL-541
2017-11-21 15:12:23 +01:00
ChrisTerBeke
657a91c525 Merge pull request #2685 from Ultimaker/container_stack_improvements
Container stack improvements
2017-11-20 17:42:26 +01:00
Lipu Fei
e246784df2 Use parseBool() for metadata bool values
CURA-4482
2017-11-17 12:43:30 +01:00
ChrisTerBeke
e23e6cfa31 Fix for global quality in case of user created quality profile - CURA-4482 2017-11-01 13:59:21 +01:00
ChrisTerBeke
957009a768 Fix finding global quality for multi extrusion machines - CURA-4482 2017-10-31 17:32:21 +01:00
ChrisTerBeke
2e1da58570 Cleanup - CURA-4482 2017-10-31 17:06:34 +01:00
ChrisTerBeke
e7f1900f71 Remove layer height from custom profiles in dropdown as it might have changed - CURA-4482 2017-10-31 14:01:15 +01:00
ChrisTerBeke
569047693e Rename loop variable to be more explicit - CURA-4482 2017-10-31 13:55:47 +01:00
ChrisTerBeke
bc6984a0ed Fixes for selecting active variant, material and quality - CURA-4482 2017-10-31 13:19:28 +01:00
ChrisTerBeke
f36c9ffbc0 Create extruder stack for single extrusion machines when adding new machine - CURA-4482 2017-10-31 09:49:24 +01:00
Chris ter Beke
9806ec7374 Resolve merge conflicts with master - CURA-4482 2017-10-31 09:22:03 +01:00
ChrisTerBeke
d718e6e36c Create extruder stack for single extruder machines on start - CURA-4482 2017-10-31 09:08:20 +01:00
Ghostkeeper
839c8ccc52
Fix 'Could not get metadata of container <empty string>'
Turns out that the side bar header was requesting the metadata before the active material was set. Now I'm just saying that if the active material was not set, it should not be compatible.

Contributes to issue CURA-4243, side-ways.
2017-10-30 11:15:41 +01:00
Diego Prado Gesto
fb88dd6326 CURA-4492 Postponed signals are now emitted even if we need user
interaction when changing quality profiles
2017-10-27 13:32:51 +02:00
ChrisTerBeke
b91824aab1 Move towards making extruder manager a first class citizen - CURA-4482 2017-10-26 17:54:36 +02:00
ChrisTerBeke
8378c6f3c9 Always add extruder quality changes when getting quality changes by name - CURA-4482 2017-10-26 14:30:18 +02:00
ChrisTerBeke
d6ef96a825 Add todo comment 2017-10-26 14:07:47 +02:00
ChrisTerBeke
0021dee84b Always use extruder stacks when copying value to all extruder - CURA-4482 2017-10-26 14:04:05 +02:00
ChrisTerBeke
0b57096056 Always use extruder stacks when switching global container in machine manager - CURA-4482 2017-10-26 13:44:47 +02:00
ChrisTerBeke
7975420901 Always set active extruder index when loading active machine on start - CURA-4482 2017-10-26 13:34:59 +02:00
Lipu Fei
2f441ba7e1 Remove debugging log lines
CURA-4451
2017-10-26 11:36:59 +02:00
Chris ter Beke
b95ba24530 Remove some changes, debugging - CURA-4451
WIP - CURA-4451

correctly show not supported when any of the extruders has a not supported profile - CURA-4451

Clean up and add comments - CURA-4451
2017-10-26 09:23:27 +02:00
ChrisTerBeke
c1139c5c45 Update stack error checking when switching matchines - CURA-4447 2017-10-24 13:38:14 +02:00
ChrisTerBeke
d2ef373d19 Also apply container changes when no user interaction is required - CURA-4447 2017-10-23 15:50:42 +02:00
ChrisTerBeke
e63616ca41 Update method description - CURA-4447 2017-10-23 11:43:15 +02:00
ChrisTerBeke
2361e96e29 Wait with updating active stack variant and material until dialog was closed - CURA-4447 2017-10-23 11:41:20 +02:00
Ghostkeeper
6c4c7fff4d
Use findContainersMetadata whenever possible
This ensures that we only load those containers that we actually need the data of.

Contributes to issue CURA-4243.
2017-10-20 15:09:45 +02:00
ChrisTerBeke
95a2559607 indent 2017-10-20 12:34:35 +02:00
ChrisTerBeke
31a04ed8da Also emit active quality changed when no dialog interaction occured - CURA-4447 2017-10-20 11:37:45 +02:00
ChrisTerBeke
70cf86c65b Remove debug print - CURA-4447 2017-10-19 14:40:56 +02:00
ChrisTerBeke
e9336b9b9e Small cleanups for discard or keep behavior - CURA-4447 2017-10-19 14:39:32 +02:00
Lipu Fei
d735921d42 Take into account the keep/discard interaction when emitting signals
CURA-4248

When user switches to a different profile, the keep/discard dialog can
show up. Don't emit signals immediately if this interaction takes place
because it will trigger an unnecessary slice.
2017-10-19 08:32:26 +02:00
A.Sasin
85f2a7c385 Added update to for Instance container to re calculate values and validate
CURA-4447
2017-10-17 15:01:49 +02:00
Lipu Fei
9b8dc9bf55 Move simple-mode settings customization check into a separate file
CURA-4333

Simple-mode is a special mode so it makes more sense to put those code
in a separate file instead of in the more generic MachineManager.
2017-10-16 13:18:11 +02:00
Lipu Fei
94a624e105 Merge branch 'master' into CURA-4333_Notification_icon_for_recommended_mode 2017-10-16 11:37:55 +02:00
A.Sasin
61cdfcd3e8 Added coments and simplified "user" metadata check
CURA-4333
2017-10-13 16:59:29 +02:00
A.Sasin
7f5aed7ead User pyqtProperty instead of puqtSlot
CURA-4333
2017-10-13 16:34:49 +02:00
Mark
c2515ca7a9 Merge branch '3.0' 2017-10-13 16:21:54 +02:00
Diego Prado Gesto
3ea9c3856c CURA-4450 Updating UI after removing printer
When removing a printer, the new one was activated but not signals were
emitted so the UI didn't update correctly. Now the printer is added and
signals are emitted.
2017-10-13 13:06:48 +02:00
A.Sasin
16bd4430e4 Added a pyQtProperty to validate user settings (Might be wrong approach)
CURA-4333
2017-10-12 21:23:17 +02:00
Lipu Fei
39891551e3 Fix custom profile handling for quality slider
CURA-4333
2017-10-12 12:42:18 +02:00