24 Commits

Author SHA1 Message Date
Ghostkeeper
1bcdc0357e
If there is no added printer, disallow closing the window
The state of having no printer added is very weird to the user. Let's prevent that from happening by accident.

Contributes to issue CURA-4736.
2017-12-29 14:32:43 +01:00
A.Sasin
3082038261 Fixed code style and machine default name is retrieved from machine definition
CURA-4345
2017-09-29 13:52:00 +02:00
alekseisasin
2a302a3e27 Merge branch '3.0' of github.com:Ultimaker/cura into 3.0 2017-09-28 13:24:13 +02:00
alekseisasin
5402092bb4 During adding a new printer the printer name generated from default name and not from custom name (changed by user)
CURA-4345
2017-09-28 13:22:15 +02:00
Mark
9a193ad5c5 Changing AGPLv3 to LGPLv3 2017-09-28 13:00:43 +02:00
Ghostkeeper
7a9a4ae290
Revert "Change Label to Text because of ugle font rendering"
This reverts commit 8c9eccd1f4f49a0d0584b3f56985f4fa16e48915. This element is in a modal window, where the fonts should get the system themeing.
2017-05-02 12:58:29 +02:00
Mark
8c9eccd1f4 Change Label to Text because of ugle font rendering
CURA-3389
2017-04-18 12:11:02 +02:00
fieldOfView
a823980d17 Replace "transparent" Rectangles by Items 2017-01-25 15:21:37 +01:00
fieldOfView
cbf553aad1 Fix scale of Add Machine and Select (Per Object) Settings dialogs...
... on fairly high, but non-"retina" screens.

I have a new laptop with a 13" 1080p display, which I use at its native resolution. This works fine for most dialogs, except the mentioned two which are shown comically large.
2016-12-23 12:55:16 +01:00
fieldOfView
d145eb1f67
Add label to machine name input field 2016-12-14 12:37:52 +01:00
fieldOfView
002605f666
Fix selecting a printer from the current section when switching sections
Broken since this change: 42fc25ab09abd044fcd3a12e87586b4edb286460
2016-12-14 12:37:51 +01:00
fieldOfView
ca20446752
Increase size of machine sections to include the full section name 2016-12-14 12:37:51 +01:00
fieldOfView
0561419a4f
Fix bottom of ("other") printer list being overlapped by machine name 2016-12-14 12:37:44 +01:00
Ghostkeeper
717248bd78
Limit number of special characters
There is also a more advanced attempt that allows more, but I've commented it out because it doesn't quite work yet. Special characters now always count for 12.

Contributes to issue CURA-2652.
2016-10-27 21:55:58 +02:00
fieldOfView
78848567e0 Add printer when pressing enter in Add Printer page instead of closing page
CURA-1354
2016-08-05 16:04:51 +02:00
fieldOfView
42fc25ab09 Move sorting of DefinitionContainerModel out of qml
Add printer dialog now has sections by a configurable metadata property. A prefered section is set to always show on top.
Add weights to the Ultimaker printer definitions to create a sensible list (newest on top).

CURA-1593
2016-08-01 19:18:56 +02:00
fieldOfView
0c8d0a11a9 Fix a couple of qml casting errors 2016-08-01 15:22:21 +02:00
fieldOfView
34840d42bd Sort printers by category instead of by manufacturer
Always show Ultimaker on top. CURA-1593
2016-07-29 16:38:27 +02:00
Jaime van Kessel
8cfc0737ac First run actions are now properly handled
CURA-1385
2016-06-22 11:49:35 +02:00
fieldOfView
c592d71051 Make "save" button on AddMachineDialog translatable
CURA-1278
2016-06-12 15:58:52 +02:00
Jaime van Kessel
44f5559db3 Moved addMachine to machineManager
CURA-1278
2016-05-12 15:18:13 +02:00
Arjen Hiemstra
3a99a2bc45 Import the right version of the UM module
Since it was changed to 1.2 for the setting models
2016-05-10 17:28:41 +02:00
Jaime van Kessel
162295da8e Actually adding a new machine is now possible
CURA-1278
2016-05-10 13:31:26 +02:00
Jaime van Kessel
1b9c29579b Reworked add machine (Still stub)
CURA-1278
2016-05-09 14:55:01 +02:00