16117 Commits

Author SHA1 Message Date
Diego Prado Gesto
2d300ab395 Revert "Fix plugins import in CuraApplication"
This reverts commit e87f3d7ca9cf135142bee488f188b9639c8b38fd.
2018-09-20 18:34:08 +02:00
alekseisasin
520a181f88
Merge pull request #4383 from Ultimaker/check_setting_visibility
Test incremental inclusion of setting visibility presets
2018-09-20 16:41:58 +02:00
Jaime van Kessel
2dbaa304a0 Set textFormat for the setting items to PlainText
Based on the Qt guide on making qml run much faster, it seems that the default of textFormatting (auto)
is quite expensive. As we make a *lot* of settingItems, which we don't want to format, it's better to set it to plain.
I haven't checked how much faster it actually is, but i didn't see visual changes, so it's at least a safe step.
2018-09-20 15:22:35 +02:00
Lipu Fei
0bc91132ed Fix check_setting_visibility return value 2018-09-20 15:18:58 +02:00
Lipu Fei
884c5dea67 Add check_setting_visibility.py to Jenkinsfile 2018-09-20 15:14:50 +02:00
Lipu Fei
72b3f9eb2a Remove debugging lines 2018-09-20 15:12:54 +02:00
Lipu Fei
2c571d5886 Rework check_setting_visibility.py 2018-09-20 15:11:41 +02:00
Lipu Fei
eb114a8529 chmod a+x check_setting_visibility.py 2018-09-20 13:50:06 +02:00
Lipu Fei
5fc8b95425 Better data handling
CURA-5095

Avoid missing sections/options
2018-09-20 12:59:27 +02:00
Lipu Fei
5a235a59dd Reset send slice info and show privacy dialog
CURA-5095

Because the data Cura collects has been changed.
2018-09-20 12:55:30 +02:00
Lipu Fei
6535f7890b Merge remote-tracking branch 'origin/3.5' 2018-09-20 10:26:17 +02:00
Lipu Fei
f912630d17
Merge pull request #4391 from Ultimaker/CURA-5095_collect_user_modified_settings
Cura 5095 collect user modified settings
2018-09-20 10:13:27 +02:00
Diego Prado Gesto
7ce3521831 Merge branch '3.5' 2018-09-20 08:57:50 +02:00
Diego Prado Gesto
4111318c7a Remove duplicate shortcut in French, so the CI won't fail on it. 2018-09-20 08:56:01 +02:00
Ghostkeeper
f99c48575e
Merge branch '3.5' 2018-09-19 17:31:52 +02:00
Ghostkeeper
ea4015c2cf
Fix missing report links
My IDE crashed while doing a replace all. I see that it missed a few.

Contributes to issue CURA-5741.
2018-09-19 17:31:39 +02:00
Ghostkeeper
95c9f9a2d5
Merge branch '3.5' 2018-09-19 17:27:00 +02:00
Ghostkeeper
ec42a96179
Update version number and fix reporting link
I don't know, did we always have it refer to Uranium's issues page?

Contributes to issue CURA-5741.
2018-09-19 17:25:57 +02:00
Ghostkeeper
f6b56a6506
Merge branch '3.5' 2018-09-19 17:16:14 +02:00
Ghostkeeper
91ed1171c2
Update translation sources for Cura 3.5
This is updated from the new cura.pot template.

Contributes to issue CURA-5741.
2018-09-19 17:15:09 +02:00
Ghostkeeper
f9923e5fe7
Remove duplicate messages
These were duplicate because CMake of this plug-in put a copy of the JSON file in the build directory.

Contributes to issue CURA-5741.
2018-09-19 17:13:53 +02:00
Ghostkeeper
10e0175947
Update translation templates for Cura 3.5
These are the new strings for Cura 3.5.

Contributes to issue CURA-5741.
2018-09-19 17:10:58 +02:00
Ghostkeeper
04b74d2285
Fix typo in Extra Infill Wall Count description
Some very observant user found this small typo. Thanks.
2018-09-19 13:58:09 +02:00
Ian Paschal
7ad6fc4cad
Merge pull request #4385 from Ultimaker/monitor_confirmation_dialogues
Add confirmation dialogues before making destructive changes in UM3/S5 monitor
2018-09-19 13:14:39 +02:00
Aleksei S
cb49ffa2d2 Updated the script according to the requested changes
CURA-5734
2018-09-18 17:42:01 +02:00
Ghostkeeper
28f743c9f4
Merge branch '3.5' 2018-09-18 17:30:08 +02:00
Ghostkeeper
44d828d137
Merge branch 'CURA-5725_simulation_stop_key_press' into 3.5 2018-09-18 17:29:35 +02:00
Diego Prado Gesto
ed9b0dd41b Add a missing bracket back.
Contributes to CURA-5725.
2018-09-18 17:25:35 +02:00
Ghostkeeper
e5154e90a7
Merge branch '3.5' 2018-09-18 17:19:03 +02:00
Ghostkeeper
e41361a053
Fan speed override is about supported areas, not bridged areas
This is a correction suggested by Smartavionics (the author of that setting) on the Ultimaker forum thread about the 3.5 beta.
2018-09-18 17:18:37 +02:00
Diego Prado Gesto
13cab3653e Remove unworking code that I forgot to remove after explaining a
possible solution to myself.

Contributes to CURA-5725
2018-09-18 17:09:57 +02:00
Diego Prado Gesto
c31f584e5b Fix my own mistake. The keys act throught the labels and the function in
the labels is called setValue that then points to the setValueManually.

Contributes to CURA-5725.
2018-09-18 17:04:24 +02:00
Diego Prado Gesto
0ef46feeae Fix code style.
Contributes to CURA-5725.
2018-09-18 16:53:25 +02:00
Diego Prado Gesto
f965b66c87 Stop the simulation also when the range slider is used. Reuse some code.
Contributes to CURA-5725.
2018-09-18 16:30:15 +02:00
Lipu Fei
3b62284276 Merge remote-tracking branch 'origin/3.5' 2018-09-18 16:15:55 +02:00
Lipu Fei
eafd856a14 Merge branch '3.5' of github.com:Ultimaker/Cura into 3.5 2018-09-18 16:11:46 +02:00
Diego Prado Gesto
e28b662649 Clean up the code a bit and update comments.
Contributes to CURA-5736.
2018-09-18 16:04:31 +02:00
Lipu Fei
a33ce8178a Support mulitple bundled_packages JSON files
CURA-5718
2018-09-18 15:53:56 +02:00
Lipu Fei
9924e3e26c Remove duplicated code
CURA-5735
2018-09-18 15:08:55 +02:00
Aleksei S
1b1ca8a53b Fix, simulation did not play after second layer
CURA-5725
2018-09-18 14:39:43 +02:00
Aleksei S
f33576cc81 Stop simulation after pressing Up or Down in simulation layer textfield
CURA-5725
2018-09-18 13:56:20 +02:00
Lipu Fei
ddc5d983a1 Fix single extrusion machines without an ExtruderStack
CURA-5736
2018-09-18 13:35:25 +02:00
Ghostkeeper
e5778be887
Corrections to change log
One was missing. One was confusing. One was incomplete.

Contributes to issue CURA-5710.
2018-09-18 12:41:44 +02:00
Ghostkeeper
3a096cdb23
Add confirmation dialogue for deleting jobs
Re-using MessageDialog again.

Contributes to issues CL-1053 and CURA-5729.
2018-09-18 11:42:34 +02:00
Ghostkeeper
83528ffb48
Add confirmation dialogue for sending prints to top of queue
Very simple. Just re-use the MessageDialog component.

Contributes to issues CL-1053 and CURA-5729.
2018-09-18 11:41:51 +02:00
Ghostkeeper
ac4ee8c428
Fix context of pause, resume and abort labels
More in line with what we have in the rest of our code base.

Discovered during work on CL-1053 and CURA-5729.
2018-09-18 11:25:35 +02:00
Ghostkeeper
a7a022eca0
Add confirmation dialogue before aborting a print
It's a destructive operation so we should ask first.

Contributes to issue CL-1053 and CURA-5729.
2018-09-18 11:24:30 +02:00
Aleksei S
c764b31e06 Update unit test for 'visibilit_settings' and removed unused settings from expert.cfv
CURA-5734
2018-09-18 11:10:24 +02:00
Lipu Fei
725ea847a7 Add material_diameter into fdmprinter
When saving a material to a file, it will save all the settings in that
container, which needs to create SettingInstances for all the cached
ones, and for those instances, their definitions will be retrieved from
the machine definition.

material_diameter is one of the settings, but it only exists in the
extruder definitions, so when it tries to save a material profile, a lot
of warnings/errors will occur due to the missing "material_diameter" in
fdmprinter. Adding it back fixes this problem.
2018-09-18 10:35:44 +02:00
Ghostkeeper