Humsie
21baf90ec8
Add Z Position parameter to FilamentChange ( #9658 )
...
* Add Z Position
* PR Comment: Add minimum value for z_position
Co-authored-by: Konstantinos Karmas <konskarm@gmail.com>
2021-05-21 17:02:53 +02:00
Ghostkeeper
84fc35abc2
Default to using customised configuration rather than firmware
...
Not all printers support a firmware configuration here. Wouldn't want to ruin some people's old prints by adding unsupported commands in there, nor change the tried-and-true old parameters people already tested with.
Contributes to issue CURA-8219.
2021-05-05 14:52:21 +02:00
Ghostkeeper
bed255ecb9
Simplify if/else statement
...
This deduplicates some code and makes it generally easier to read.
Contributes to issue CURA-8219.
2021-05-05 14:50:43 +02:00
Ghostkeeper
e1e25d629e
Use more neutral setting and variable names
...
It may be just Marlin that implements this right now, but that is bound to change.
Contributes to issue CURA-8219.
2021-05-05 14:49:41 +02:00
Sekisback
b458005e7e
add Marlin Advanced Pause Feature!
2020-12-24 09:46:19 +01:00
Nino van Hooff
89f0970a88
Remove trailing whitespace from Python files
2020-05-29 14:30:33 +02:00
Nino van Hooff
a4fe3d7685
Convert doxygen to rst for POS, MonitorStage, PostProcessing
2020-05-08 16:28:07 +02:00
Cherubim
e1bb783bcd
Better bounds checking in layer numbers
2019-05-28 14:38:19 +02:00
Ghostkeeper
c9e7f3a245
Fix finding layer numbers
...
That seems to have been unreliable. Luckily the original g-code is already broken up in layers, so searching it is completely unnecessary.
Hopefully resolves issue #5630 .
2019-05-06 11:47:13 +02:00
Ghostkeeper
fdc629de32
Make error message log which layer could not be found
2019-04-15 13:17:31 +02:00
Ghostkeeper
5592d4fa60
Don't make retraction distance negative
...
Apparently this got changed accidentally because of a merge in an unfortunate time.
2019-02-04 08:25:35 +01:00
griehsler
3a84a5868f
Merge branch 'master' into master
2018-10-31 21:44:44 +01:00
Ghostkeeper
c7b146c9fc
Don't make retract distances negative
...
People are reporting that the retraction is reversed. We can't test it since we have no firmware that supports the command at all. So we'll just not make the retract distance negative. That seems more logical anyway if you read the documentation of M600 to the letter.
Fixes #4249 .
2018-10-25 13:54:00 +02:00
griehsler
5ae5dfd3ad
added x_position and y_position to postprocessing filamentchange parameters
2018-10-20 01:28:48 +02:00
Diego Prado Gesto
296b74b032
Set negative values to retraction in the filament change script.
...
Fixes #4114
2018-07-24 10:48:52 +02:00
Diego Prado Gesto
2c7c167fe0
CURA-5335 Looking for the actual line number in the gcode when using the filament change script.
2018-06-13 20:41:56 +02:00
Ghostkeeper
4226f3641b
Better defaults for filament change
...
And better descriptions.
2018-03-21 17:12:54 +01:00
Ghostkeeper
ecfb62b69e
Rename ColorChange to FilamentChange
...
I think this is more clear to the users what this should actually do.
2018-03-07 11:01:00 +01:00