Ghostkeeper
89fc4c94bf
Add version upgrade for changed Redo Layer parameter of Pause script
...
This was changed from a number of layers to just a boolean for 1 or 0 layers.
Contributes to issue CURA-7413.
2020-05-11 18:50:49 +02:00
Ghostkeeper
aff28d821f
Also reset extrusion for Griffin printers
...
The rest may not be necessary but the G92 is crucial if redo layer is activated.
Contributes to issue CURA-7413.
2020-05-11 18:35:27 +02:00
Ghostkeeper
05b0bf5988
Turn 'Redo Layers' into a boolean for at most 1 layer
...
We've deemed it irresponsible to redo multiple layers. This will dig the nozzle back down into the layers that were printed before the pause.
This doesn't include a version upgrade yet.
Contributes to issue CURA-7413.
2020-05-11 18:34:41 +02:00
Ghostkeeper
1946615fff
Fix asynchronous bug if job gets cancelled
...
If the print job happens to get cancelled right after checking if the index is correct, but before actually reading the line, it would get an IndexError when trying to read the line since cancelling the job clears the _gcode list.
This prevents that asynchronous issue by using the internal check in the list access to check that, and just uses an exception to check whether it's reached the end.
Fixes Sentry issue CURA-QC.
2020-05-11 17:36:24 +02:00
Konstantinos Karmas
ff8e037f4c
Merge pull request #7704 from Ultimaker/CURA-7429_fix_image_reader_peak_height
...
CURA-7429_fix_image_reader_peak_height
2020-05-11 13:58:11 +02:00
Konstantinos Karmas
6ea37603f2
Merge pull request #7715 from Ultimaker/CURA-7420_fix_version_upgrader
...
New version upgrade for 4.7
2020-05-11 11:07:44 +02:00
Konstantinos Karmas
0bcb3348da
Merge pull request #7707 from Ultimaker/CURA-7245_fix_bundled_package_sync
...
CURA-7245_fix_bundled_package_sync
2020-05-11 09:49:19 +02:00
Nino van Hooff
a09cd0e63e
Convert doxygen to rst for Prepare, Preview, RemovableOutputDevice
2020-05-08 17:37:49 +02:00
Nino van Hooff
a4fe3d7685
Convert doxygen to rst for POS, MonitorStage, PostProcessing
2020-05-08 16:28:07 +02:00
Nino van Hooff
553b09b6cf
Convert doxygen to rst for GcodeWriter, LegacyProfileReader,
...
MachineSettingsAction, ModelChecker
2020-05-08 16:20:55 +02:00
Nino van Hooff
40327c4259
Convert doxygen to rst for GcodeReader, GcodeGzReader/Writer,
...
GCodeProfileReader
2020-05-08 15:58:51 +02:00
Nino van Hooff
6ca9b4678e
Convert doxygen to rst for Firmware update plugins
2020-05-08 15:46:02 +02:00
Nino van Hooff
54d2fe95d1
Convert doxygen to rst for CuraProfileReader/Writer
2020-05-08 15:43:12 +02:00
Nino van Hooff
176919eee0
Merge branch 'master' into doxygen_to_restructuredtext_comments
...
# Conflicts:
# plugins/CuraEngineBackend/CuraEngineBackend.py
# plugins/CuraEngineBackend/StartSliceJob.py
2020-05-08 15:31:23 +02:00
Nino van Hooff
797d6ed438
Convert doxygen to rst for CuraEngineBackend
2020-05-08 15:23:51 +02:00
Nino van Hooff
8f3827d5ae
Convert doxygen to rst for 3MFReader/Writer and AMFReader
2020-05-08 15:14:39 +02:00
Nino van Hooff
1ae050bbc5
Expose Account.SyncState as an Enum to QML
...
Provides a single source of truth
CURA-7290
2020-05-08 11:09:48 +02:00
Ghostkeeper
c3c144345b
Add version upgrade to halve the maximum deviation once again
...
As explained in the comment. We reverted a change in 4.6, so we must unrevert it in master again.
Contributes to issue CURA-7420.
2020-05-08 09:30:54 +02:00
Ghostkeeper
b02354b209
Merge branch '4.6'
...
Conflicts:
plugins/VersionUpgrade/VersionUpgrade460to462/VersionUpgrade460to462.py -> On master we removed the getCfgVersion function, while we moved the entire plug-in to a different folder in 4.6.
resources/definitions/skriware_2.def.json -> On master we merged a PR that changes more or less all settings, while on 4.6 we doubled the maximum deviation.
2020-05-08 09:10:02 +02:00
Remco Burema
23cdf871c1
Add comments: Why a matrix4x4 and not a sampler1d?
...
part of CURA-7426
2020-05-07 18:55:55 +02:00
Nino van Hooff
5a3bcb6161
Fix image reader peak height
...
CURA-7429
2020-05-07 14:29:30 +02:00
Kostas Karmas
6ffd250965
Format spacing
...
CURA-7426
2020-05-07 14:10:45 +02:00
Remco Burema
99e99e4650
Layerview can now deal with visibility extruder nrs. 4+
...
part of CURA-7426
2020-05-06 18:03:32 +02:00
Nino van Hooff
9b79b70f2b
Merge branch 'CURA-7290_auto_sync_packages' into CURA-7290_manual_account_sync
...
# Conflicts:
# cura/API/Account.py
# plugins/UM3NetworkPrinting/src/Cloud/CloudOutputDeviceManager.py
2020-05-06 16:03:37 +02:00
Nino van Hooff
3ac0e7bed9
Consider all packages when calculating account discrepancies
...
Not just the user-subscribed ones
CURA-7245
2020-05-06 16:01:36 +02:00
Nino van Hooff
bfae7e9fb1
Replace some hard-coded sync states
...
CURA-7290
2020-05-06 12:54:07 +02:00
Remco Burema
2687578a86
Merge pull request #7624 from Ultimaker/CURA-7022_Add_cloud_printer_within_add_a_connected_printer
...
Cura 7022 add cloud printer within add a connected printer
2020-05-06 11:13:27 +02:00
Nino van Hooff
5b245434d0
Add _last_check_packages type hint
...
CURA-7290
2020-05-04 17:32:54 +02:00
Nino van Hooff
eac884fcd2
Convert SYNC_STATES to Enum
...
CURA-7290
2020-05-04 17:26:38 +02:00
Nino van Hooff
88ff68e40c
Also check for package updates automatically
...
Moves the 30-second sync timer from CloudOutputDeviceManager to
Account and subscribes CloudPackageChecker to the timer.
CURA-7290
2020-05-04 16:56:09 +02:00
Nino van Hooff
eeea1692fd
Register CloudPackageChecker as Account sync service
...
CURA-7290
2020-05-04 14:08:36 +02:00
Nino van Hooff
049c1946d4
Create Account sync state interface to allow for multiple sync services
...
Needed to add the package sync
CURA-7290
2020-05-04 13:52:40 +02:00
Kostas Karmas
69f23eca94
Double the maximum deviation again in the versionUpgrade460to462
...
CURA-7421
2020-05-04 13:22:22 +02:00
Nino van Hooff
81d02d5d58
Implement printer cloud sync error state
...
CURA-7290
2020-05-04 13:19:16 +02:00
Kostas Karmas
96fde43ae8
Up the setting version inside the VersionUpgrade460to462
...
CURA-7421
2020-05-04 13:12:17 +02:00
Kostas Karmas
aab2257574
Up the setting version to 14 in CuraApplication
...
CURA-7421
2020-05-04 13:06:19 +02:00
Kostas Karmas
74bc40eb90
Add version upgrade 460to462
...
CURA-7421
2020-05-04 13:03:21 +02:00
Kostas Karmas
524a072420
Merge version upgrade 45to46 with 46to47
...
CURA-7421
2020-05-04 13:00:17 +02:00
Nino van Hooff
0aed6d3731
Connect the manual sync button
...
CURA-7290
2020-05-01 15:56:09 +02:00
Jaime van Kessel
245a4435e1
Also handle sceneChanged when it's from the root
...
The rest of the code also seems to expect that
2020-05-01 14:39:23 +02:00
Kostas Karmas
80a4cfbd75
Remove duplicated line
...
This line is called both outside and inside of _setOutputDeviceMetadata(...)
CURA-7055
2020-04-30 14:03:34 +02:00
Jaime van Kessel
db7429488d
Merge branch 'del_scripts_pycache' of github.com:Ultimaker/Cura
2020-04-30 13:50:57 +02:00
Kostas Karmas
b008f1e823
Merge branch 'master' into CURA-7022_Add_cloud_printer_within_add_a_connected_printer
2020-04-29 15:37:53 +02:00
Kostas Karmas
61e2cc1193
Fix missing type for result
2020-04-29 15:33:28 +02:00
Jaime van Kessel
1775903335
Merge branch 'CURA-7404_fix_xray_green' of github.com:Ultimaker/Cura
2020-04-29 14:59:53 +02:00
Ghostkeeper
dfa021ab20
Fix upgrade of preference if visible settings was not modified
...
Oops. Small oversight. This could lead to the preferences file being erased completely.
Found during work on Sentry issue CURA-NH.
2020-04-29 14:10:07 +02:00
Ghostkeeper
abffb6c26c
Don't crash when reading corrupt 3MF files
...
Otherwise it would crash with a BadZipFile error. We should be robust against that. This will trigger a generic message that we couldn't read that file to the user, and put more information in the log.
Fixes Sentry issue CURA-NH.
2020-04-29 14:07:04 +02:00
Ghostkeeper
dcac9b6a87
Prevent a crash when retrying even though it completed in the meanwhile
...
Fixes Sentry issue CURA-NA.
2020-04-29 14:07:03 +02:00
Ghostkeeper
bf3d6c67d9
Check the bounding box before using it
...
Some objects don't have a bounding box if they are improperly constructed by a plug-in.
Fixes Sentry issue CURA-N3.
2020-04-29 14:07:03 +02:00
Jaime van Kessel
084e80bcda
Only connect a cloud printer if it's the active one
...
By splitting up the correctly setting of metadata and actually
connecting, the distinction can be made.
CURA-7055
2020-04-29 13:48:06 +02:00