material_shrinkage_percentage_xy and material_shrinkage_percentage_z cannot depend on material_shrinkage_percentage otherwise their resolve function will not execute properly.
I noticed that the shrinkage factors do not get the correct value if a wrong nozzle is chosen for a material. However, in that case the slicer will also not slice, so in practice this is not an issue
Relates to PP-77
This causes a binding loop when using layouts like Column.
To resolve this the height/width of the popup in ExpandablePopup can now be set explicitly with contentWidth and contentHeight
For ExpandablePopups with contentItems that are not Layouts the implicitWidth/implicitHeight can be set directly in the contentItem.
CURA-8640
New calculations to determine the average shrinkage when two materials are used. By default the material shrinkage is set to null (None). In that case the shrinkage of that material is not taken into account in the new averaging formula. Support materials such as PVA, BAM, Aquasys etc. should keep this setting to null. When two materials are used with a shrinkage percentage the average of these two materials will be used.
Relates to PP-77
With the increase in linewidth to the nozzle size, the material flow for especially the infill (but also inner walls) is increased. The speeds are reduced for the superdraft profiles to match the maximum material flow in CURA413. In the future we want to clean this up in a nice way, but for now this at least fixes some serious extrusion problems. PP-104
With increasing the infill linewidth, the infill line distance is increased as well. The infill density of the AA0.8 profiles is increased by 5% to the default of 20%. PP-104
We will only support the Inwards Distributed strategy type from here on out. You can achieve a similar result as that one by adjusting the Wall Distribution Count setting (1 is Center Deviation, 2 is Inwards Distributed, 999999 approximates Distributed).
Contributes to issue CURA-8466.
We've removed a bunch of settings and transformed others. To allow profiles to be checked for these and edited if necessary, we now need to increment this version number.
Contributes to issue CURA-8466.
It is no longer used since we've removed the Fill Gaps Between Walls setting. This setting is no longer referred to from CuraEngine.
Contributes to issue CURA-8466.