Conflicts:
plugins/SimulationView/SimulationPass.py -> Reverted layer view optimisation in Master while some whitespace changed in Arachne.
resources/definitions -> Bunch of conflicts with profile updates.
resources/quality -> Bunch of conflicts with profile updates.
resources/texts/change_log.txt -> Removed the Arachne change log (as they are internal versions). It'll have to be re-added when we release this version as stable.
Since the setting version 18 is used in the arachne beta build, we decided to make the the setting version to 19 in the normal releases, so that we make sure that projects made in arachne beta won't use any version upgrade scripts if a user attempts to open them in 4.12.
CURA-8510
We now have version 18, where Flsun Super Racer has customised profiles.
Nothing changes in the built-in profiles. It only needs a change in the machine instances.
Contributes to issue CURA-8510.
Although it is not entirely sure yet, we are fairly certain that libArachne release will have
a setting version of 18, so it is changed by this commit. With this change, the VersionUpgrader
will be properly triggered.
Contributes to CURA-7683 and CURA-7656
We have a change now that requires a version upgrade. This triggers all profiles to update for the user, and we must update accordingly in the built-in profiles.
Contributes to issue CURA-7118.
Given that:
* stair stepping is intended to be used to reduce the adhesion between support and the model, where the support rests on the model, and to reduce scarring, and
* PVA doesn't suffer from scarring or adhesion issues due to its water-solubility, and
* our current stair stepping algorithm has some bugs, causing support to disappear sometimes
we've decided to set stair stepping to 0 for all PVA profiles for UM3, UMS5 and UMS3.
Contributes to issue CURA-7311.
Also convert the values for prime_tower_min_volume to make it behave similar to what the minimum volume used to be. This feature fixed a bug with the computation from volume to thickness. Now it's correct but we have to correct the old values to be still the same (approximately) as what used to be the end result.
Contributes to issue CURA-5457.
- Remove "author" from "metadata" section
- Add "hardware_type" for variants that don't have it
- Reformat "metadata" section to have the following order:
- setting_version
- type
- hardware_type
CURA-4451
- Add upgrade script for 3.0. to 3.1
- Upgrade old stack files so they will use "empty_quality" as the
"Not Supported" quality profile.
- Increase SettingVersion to 4
CURA-3872
We add a new setting "machine_nozzle_type" to give the engine
information about the nozzle type, such as "AA" and "BB". This is
applicable to UM3 and UM3XL.
These are now upgraded to version 3, meaning that they will have to increase their version numbers and remove any start_layers_at_same_position settings they define. None of these profiles define any start_layers_at_same_position so it's just the version number then.
Contributes to issue CURA-3479.