Cura/plugins/UltimakerMachineActions/UMOCheckupMachineAction.py
2016-07-07 15:56:14 +02:00

181 lines
7.3 KiB
Python

from cura.MachineAction import MachineAction
from cura.PrinterOutputDevice import PrinterOutputDevice
from UM.Application import Application
from PyQt5.QtCore import pyqtSlot, pyqtSignal, pyqtProperty
from UM.i18n import i18nCatalog
catalog = i18nCatalog("cura")
class UMOCheckupMachineAction(MachineAction):
def __init__(self):
super().__init__("UMOCheckup", catalog.i18nc("@action", "Checkup"))
self._qml_url = "UMOCheckupMachineAction.qml"
self._hotend_target_temp = 180
self._bed_target_temp = 60
self._output_device = None
self._bed_test_completed = False
self._hotend_test_completed = False
# Endstop tests
self._x_min_endstop_test_completed = False
self._y_min_endstop_test_completed = False
self._z_min_endstop_test_completed = False
self._check_started = False
Application.getInstance().getOutputDeviceManager().outputDevicesChanged.connect(self._onOutputDevicesChanged)
onBedTestCompleted = pyqtSignal()
onHotendTestCompleted = pyqtSignal()
onXMinEndstopTestCompleted = pyqtSignal()
onYMinEndstopTestCompleted = pyqtSignal()
onZMinEndstopTestCompleted = pyqtSignal()
bedTemperatureChanged = pyqtSignal()
hotendTemperatureChanged = pyqtSignal()
def _onOutputDevicesChanged(self):
# Check if this action was started, but no output device was found the first time.
# If so, re-try now that an output device has been added/removed.
if self._output_device is None and self._check_started:
self.startCheck()
def _getPrinterOutputDevices(self):
return [printer_output_device for printer_output_device in
Application.getInstance().getOutputDeviceManager().getOutputDevices() if
isinstance(printer_output_device, PrinterOutputDevice)]
def _reset(self):
if self._output_device:
self._output_device.bedTemperatureChanged.disconnect(self.bedTemperatureChanged)
self._output_device.hotendTemperaturesChanged.disconnect(self.hotendTemperatureChanged)
self._output_device.bedTemperatureChanged.disconnect(self._onBedTemperatureChanged)
self._output_device.hotendTemperaturesChanged.disconnect(self._onHotendTemperatureChanged)
self._output_device.endstopStateChanged.disconnect(self._onEndstopStateChanged)
try:
self._output_device.stopPollEndstop()
except AttributeError: # Connection is probably not a USB connection. Something went pretty wrong if this happens.
pass
self._output_device = None
self._check_started = False
self.checkStartedChanged.emit()
# Ensure everything is reset (and right signals are emitted again)
self._bed_test_completed = False
self.onBedTestCompleted.emit()
self._hotend_test_completed = False
self.onHotendTestCompleted.emit()
self._x_min_endstop_test_completed = False
self.onXMinEndstopTestCompleted.emit()
self._y_min_endstop_test_completed = False
self.onYMinEndstopTestCompleted.emit()
self._z_min_endstop_test_completed = False
self.onZMinEndstopTestCompleted.emit()
@pyqtProperty(bool, notify = onBedTestCompleted)
def bedTestCompleted(self):
return self._bed_test_completed
@pyqtProperty(bool, notify = onHotendTestCompleted)
def hotendTestCompleted(self):
return self._hotend_test_completed
@pyqtProperty(bool, notify = onXMinEndstopTestCompleted)
def xMinEndstopTestCompleted(self):
return self._x_min_endstop_test_completed
@pyqtProperty(bool, notify=onYMinEndstopTestCompleted)
def yMinEndstopTestCompleted(self):
return self._y_min_endstop_test_completed
@pyqtProperty(bool, notify=onZMinEndstopTestCompleted)
def zMinEndstopTestCompleted(self):
return self._z_min_endstop_test_completed
@pyqtProperty(float, notify = bedTemperatureChanged)
def bedTemperature(self):
if not self._output_device:
return 0
return self._output_device.bedTemperature
@pyqtProperty(float, notify=hotendTemperatureChanged)
def hotendTemperature(self):
if not self._output_device:
return 0
return self._output_device.hotendTemperatures[0]
def _onHotendTemperatureChanged(self):
if not self._output_device:
return
if not self._hotend_test_completed:
if self._output_device.hotendTemperatures[0] + 10 > self._hotend_target_temp and self._output_device.hotendTemperatures[0] - 10 < self._hotend_target_temp:
self._hotend_test_completed = True
self.onHotendTestCompleted.emit()
def _onBedTemperatureChanged(self):
if not self._output_device:
return
if not self._bed_test_completed:
if self._output_device.bedTemperature + 5 > self._bed_target_temp and self._output_device.bedTemperature - 5 < self._bed_target_temp:
self._bed_test_completed = True
self.onBedTestCompleted.emit()
def _onEndstopStateChanged(self, switch_type, state):
if state:
if switch_type == "x_min":
self._x_min_endstop_test_completed = True
self.onXMinEndstopTestCompleted.emit()
elif switch_type == "y_min":
self._y_min_endstop_test_completed = True
self.onYMinEndstopTestCompleted.emit()
elif switch_type == "z_min":
self._z_min_endstop_test_completed = True
self.onZMinEndstopTestCompleted.emit()
checkStartedChanged = pyqtSignal()
@pyqtProperty(bool, notify = checkStartedChanged)
def checkStarted(self):
return self._check_started
@pyqtSlot()
def startCheck(self):
self._check_started = True
self.checkStartedChanged.emit()
output_devices = self._getPrinterOutputDevices()
if output_devices:
self._output_device = output_devices[0]
try:
self._output_device.startPollEndstop()
self._output_device.bedTemperatureChanged.connect(self.bedTemperatureChanged)
self._output_device.hotendTemperaturesChanged.connect(self.hotendTemperatureChanged)
self._output_device.bedTemperatureChanged.connect(self._onBedTemperatureChanged)
self._output_device.hotendTemperaturesChanged.connect(self._onHotendTemperatureChanged)
self._output_device.endstopStateChanged.connect(self._onEndstopStateChanged)
except AttributeError as e: # Connection is probably not a USB connection. Something went pretty wrong if this happens.
pass
@pyqtSlot()
def cooldownHotend(self):
if self._output_device is not None:
self._output_device.setTargetHotendTemperature(0, 0)
@pyqtSlot()
def cooldownBed(self):
if self._output_device is not None:
self._output_device.setTargetBedTemperature(0)
@pyqtSlot()
def heatupHotend(self):
if self._output_device is not None:
self._output_device.setTargetHotendTemperature(0, self._hotend_target_temp)
@pyqtSlot()
def heatupBed(self):
if self._output_device is not None:
self._output_device.setTargetBedTemperature(self._bed_target_temp)