Cura/resources/quality/ultimaker3/um3_aa0.4_ABS_Normal_Quality.inst.cfg
Rijk van Manen 6d489659f2 Clean up of standby temperatures
Clean up of standby temperatures to printing temperature -100deg. This is a safe default. PP-192
2022-08-29 14:52:02 +02:00

25 lines
662 B
INI

[general]
version = 4
name = Fine
definition = ultimaker3
[metadata]
setting_version = 20
type = quality
quality_type = normal
weight = 0
material = generic_abs
variant = AA 0.4
[values]
machine_nozzle_cool_down_speed = 0.85
machine_nozzle_heat_up_speed = 1.5
material_print_temperature_layer_0 = =material_print_temperature + 10
material_initial_print_temperature = =material_print_temperature - 5
material_final_print_temperature = =material_print_temperature - 10
prime_tower_enable = False
speed_print = 55
speed_layer_0 = =math.ceil(speed_print * 20 / 55)
speed_topbottom = =math.ceil(speed_print * 30 / 55)
speed_wall = =math.ceil(speed_print * 30 / 55)