update chamber temperature WIKI

This commit is contained in:
SoftFever 2023-11-12 22:10:10 +08:00
parent b1c325a419
commit 9731ea3277
2 changed files with 14 additions and 0 deletions

View File

@ -1,4 +1,18 @@
OrcaSlicer use `M141/M191` command to control active chamber heater. OrcaSlicer use `M141/M191` command to control active chamber heater.
If `Activate temperature control` is checked, OrcaSlicer will insert `M191` command at the beginning of the gcode(before `Machine G-code`).
![image](./images/activate_chamber_heater.jpg)
*Note: If the machine is equipped with an auxiliary fan, OrcaSlicer will automatically activate the fan during the heating period to help circulate air in the chamber.*
There are two chamber temperature variables available that we can use in `Machine G-code` to control the chamber temperature, if you prefer:
To access the chamber temperature set in the first filament, use:
`M191 S{chamber_temperature[0]}`
To use the overall chamber temperature, which is the highest chamber temperature set across all filaments, use:
`M191 S{overall_chamber_temperature}`
--------------------------Klipper--------------------------
If you are using Klipper, you can define these macros to control the active chamber heater. If you are using Klipper, you can define these macros to control the active chamber heater.
Bellow is a reference configuration for Klipper. Bellow is a reference configuration for Klipper.
*Note: Don't forget to change the pin name/values to the actual values you are using in the configuration* *Note: Don't forget to change the pin name/values to the actual values you are using in the configuration*

Binary file not shown.

After

Width:  |  Height:  |  Size: 10 KiB