* Added prelim support for the BX
* Revert "Added prelim support for the BX"
This reverts commit 923fbdbbb617d000663f04d08d468ed0c560517c.
* Added prelim support for the BX
* Revert "Added prelim support for the BX"
This reverts commit 923fbdbbb617d000663f04d08d468ed0c560517c.
* Added BIQU BX printer def
* Updated the platform name.
* Minor update to the start code. Ready for merge.
* Initial FLSun Super Racer profile setup.
* flip has_machine_quality to false as suggested by @konskarm.
* tabs vs spaces! Space is the final frontier!
* Enumeration value should be in inner single quotes as requested by @konskarm.
If the user had specialised settings fixing the number of walls or skin layers to an integer number, this fixed value would get copied over from the extruder settings, causing infill meshes to have walls by default.
This is unintuitive. We want infill meshes to behave like it's only infill by default. So remove all of those overrides so that only infill gets printed there, by default.
The user may still change the number of walls or skin layers or their parent settings. But by default it should now behave like infill within infill, regardless of the user's setting overrides.
Fixes issue CURA-8393 and fixes#9815.
When working with --external-backend, the engine just stops responding, and the operating system cleans up its socket connection. From Cura's front-end we then just see the socket reset. So we should interpret a reset socket to mean that the slicing process was halted.
When not working with an external backend, a crash would always give a response code and we can base it on that instead (as previously implemented).
Contributes to issue CURA-6568.
If the user has auto-slicing enabled, this causes the indeterminate progress bar to appear.
If the user doesn't have auto-slicing enabled, this causes the slice button to reappear.
Both of these indicate that something has caused slicing to be interrupted. The message should make clear why.
Contributes to issue CURA-6568.
The slicing engine should never crash. If it does though, it's best to show something to the user. Otherwise the slicing process just halts and the user will wait a long time for it to never finish.
Contributes to issue CURA-6568.
When the `_onGetProjectsFirstPageFinished` is reached, the pagination manager already contains the correct pagination metadata and links, so calling `clear()` there resets them giving the impression that there is no next page.
This commit fixed that by calling the `clear()` function should when the search filter is applied, instead.
CURA-8009
When checking whether the user is allowed to create a new library project, we need to retrieve the **private** (aka non-shared) projects that are linked to the user's account. If the user has reached the maximum private projects, then they are no longer allowed to create new ones.
**Note**: We need to set the `pagination_manager` to `None` when doing this get request, or else the next/previous links of the pagination will become mixed up with the pagination links of the list of projects shown to the user, corrupting them and creating the wrong "get more projects" link.
CURA-8112
When the tooltip text is too long and the tooltip width ends up being longer than the window it is supposed to be drawn into, the tooltip is not drawn at all. This commit fixed that by allowing the tooltip width of the ActionButton to be changed within QML, limiting it to a certain size that fits the purpose.
CURA-8112
Instead of letting users go through the project creation process only to get rejected with a "subscription limits reached" message, now the "New Library project" button is being replaced with an "Upgrade plan" button when the maximum allowed projects have been reached for the specific amount. The button is accompanied by a tooltip that explains the situation to the user. Once clicked, the user is redirected to the subscriptions page.
CURA-8112
Instead of using the default of 5 pixels, we should use this element from the theme to match the margin around the page.
Contributes to issue CURA-8009.
The margin around the icon didn't work if the icon source was none, because it was provided a QSize rather than a real.
The margin around the background didn't work at all because the background is automatically adjusted to fill the parent element, so it's best left out.
Contributes to issue CURA-8009.
Because this item is in a layout, the height gets overridden. We should use the preferredHeight, or the one it defaults to, implicitHeight.
Contributes to issue CURA-8009.
This adds an option to the TextField element to show an icon on the left side in the text field. The icon remains visible when the user types in something (it's not part of the placeholder string).
Then we use that optional icon for the search bar in the Digital Library.
Contributes to issue CURA-8009.
This is the standard style for text fields in Cura. The spacing around the search icon is customised with the best approximation I could get using a simple string of placeholderText.
Contributes to issue CURA-8009.