We know that some printers (e.g. UM3) are able to reach at least 285 degrees so we set that to be our warning value now.
The warning value for the bed temperature was probably mixed up with the warning value for nozzle temperature. Fixed that too.
All print temperatures go down 5 degrees and then in the material profile the temperature is increased by 5. This gives the normal profile a +0 instead of +5.
Contributes to issue CURA-3433.
The optimisation script didn't know that the temperature settings in material profiles now refers to default_material_print_temperature rather than material_print_temperature. This caused a few things to go wrong here.
Contributes to issue CURA-3433.
Definition files for single and dual head versions of Velleman Vertex
K8400 printer.
The machine uses printable coordinates x=0 to 200, y=20 to 200 and
parking position 200, 200 regardless of how many extruders you use.
Thereby the different machine_width for the two models.
The g-code can probably be improved.
USB connection not successful this far.
There was the problem that you'd click on pre-heat, so locally it would display the time-out. Then a package came in with the out-dated print status saying that the printer is not pre-heating, so the pre-heat was cancelled on Cura's side. Then the next status update came in saying that the pre-heat is now busy, so the pre-heat is resumed on Cura's side. So the button was flicking back and forth once after pressing. This commit makes Cura ignore any status updates that come while the put-request is still going on, because they may be outdated. It'll appear nicer to the user, mostly.
Contributes to issue CURA-3360.
If multiple instances of Cura are running or Cura is restarted, it now properly syncs the remaining pre-heat time with the printer, so that all instances display the proper time.
There's still a bug in here that pressing cancel has no effect the first time since the remaining pre-heat time is updated immediately from the printer before the command to cancel got through remotely. I'll see what I can do to amend that. Also, cancelling is not yet synced.
Contributes to issue CURA-3360.
These materials are hard-coded in the optimisation script, so the optimisation script didn't know that those materials were materials and this caused a chain reaction where in the end the profile could only override XML-settings.