75 Commits

Author SHA1 Message Date
c.lamboo
74678bf6fb Bumb version for profiles
CURA-11526
2024-03-15 11:59:09 +01:00
c.lamboo
597fbb06a0 Revert "Bumb version in profiles"
This reverts commit 3aa32298dc54f734d4ddd4fc506fb94ea86e63a2.
2024-03-15 11:44:37 +01:00
c.lamboo
3aa32298dc Bumb version in profiles
CURA-11526
2024-03-15 10:28:16 +01:00
Paul Kuiper
3b716d08b2 Removed the reduced print speed for the bottom interface layers of the BB cores (effectively for PVA).
Relates to PP-328
2023-04-14 09:52:43 +02:00
Jelle Spijker
28d6e993df
Bump up setting version to 22 2023-03-31 07:24:43 +02:00
jspijker
d2f5d059cb Bump up the settings version to 21 in profiles/definitions
Contributes to CURA-10077
2023-01-30 11:40:04 +01:00
Rijk van Manen
76a6e394d6 follow the default settings
PP-71
2023-01-24 11:26:45 +01:00
jspijker
53d8e0c730 Applied printer-linter format
To make sure we have uniform diffs with our PR's
2022-12-30 22:05:41 +01:00
Rijk van Manen
27d56d378e improve initial layer settings
ultimaker.def.json is also cleaned and put in alphabetic order.
Ultimaker 2 and original are kept mostly as they were, since they are not tested. PP-42
2022-10-06 16:11:04 +02:00
Rijk van Manen
179e6bdfb6 cleanup raft speeds
raft base speed is only 15mm/s to avoid extreme flows. The raft surface speed equals the top/bottom speed, so the raft surface has a flow equal to the top/bottom flow. The raft interface is again the average of the surface and the base. PP-243
2022-09-13 11:18:38 +02:00
Rijk van Manen
cb07fefdf2 increase retract distance of PVA to default
PVA is stringing a lot due to the too small retract distance. This oozed material is causing under extrusion elsewhere, reducing the strength of the support. Too long retractions could cause reliability issues as well. However, since we reduced the number of retractions by ~40% for the smaller models (for bigger models it is ~0%, but then it is also not relevant since a lot of material is printed in between) with the new settings of PP-108 increasing the retract distance to 6.5mm is safe. PP-185
2022-06-28 14:03:01 +02:00
Jaime van Kessel
3689c097f3 Re-add accidentally removed setting 2022-06-17 15:54:23 +02:00
p.kuiper
e4b6c93c4c Cleaning up support settings in the variant files.
Relates to PP-108
2022-06-03 14:03:22 +02:00
Jaime van Kessel
952da63230
Merge pull request #12415 from Ultimaker/PP-170-clean-up-retraction_count_max
Pp 170 clean up retraction limits
2022-06-02 17:05:57 +02:00
p.kuiper
a103d377f7 Further cleanup of the jerk settings. UM2 based machine have no jerk settings, removed them. Set first layer jerk equal to print jerk and removed all jerk settings (except for jerk_print) in the quality and variant files.
Relates to PP-19
2022-06-02 11:33:22 +02:00
Rijk van Manen
3a2a58f546 remove setting, follow the default
PP-170
2022-06-01 15:16:23 +02:00
Ghostkeeper
d9d90ab4b6
Increment setting_version to 20
We've removed a bunch of settings and transformed others. To allow profiles to be checked for these and edited if necessary, we now need to increment this version number.

Contributes to issue CURA-8466.
2022-03-29 15:03:48 +02:00
Ghostkeeper
9140b71b19
Merge branch 'libArachne_rebased'
Conflicts:
	plugins/SimulationView/SimulationPass.py -> Reverted layer view optimisation in Master while some whitespace changed in Arachne.
	resources/definitions -> Bunch of conflicts with profile updates.
	resources/quality -> Bunch of conflicts with profile updates.
	resources/texts/change_log.txt -> Removed the Arachne change log (as they are internal versions). It'll have to be re-added when we release this version as stable.
2021-12-14 11:48:58 +01:00
Remco Burema
8c8ec5391f
Revert settings-version to the one for Arachne-builds. 2021-10-20 11:01:13 +02:00
Remco Burema
86046a32b3
Merge branch 'master' into merge_main_20211019 2021-10-20 08:38:01 +02:00
Remco Burema
2fc20fd04a
Prep for merge with main branch. Setting-version 18 to 19. 2021-10-19 18:32:51 +02:00
p.kuiper
0239ce8a78 - Bug fix error due to string overrides.
- "Minimum_value" changed to "minimum_warning_value"
- PVA (BB0.4 and BB0.8) require low support jerk settings for good adhesion
- Support roof does follow print_jer and no warning levels set
2021-10-11 13:53:21 +02:00
p.kuiper
6c67b03a55 - Reverted the print profiles to changes agreed by the Print Profile CCB from 06-10-2021 14:00-15:00 2021-10-11 11:35:38 +02:00
p.kuiper
f9f59d0da1 Merge branch 'master' into PP-1-Improved_print_profiles
# Conflicts:
#	resources/definitions/ultimaker_s3.def.json
#	resources/definitions/ultimaker_s5.def.json
2021-09-29 17:33:02 +02:00
p.kuiper
ec096a12f6 Also add minimal jerk of 20mm/s to S3 and UM3. 2021-09-24 10:01:15 +02:00
THeijmans
a698409a25 Set line widths equal to nozzle diameter
and remove line width lines from profiles (PP-13)
2021-09-16 10:27:44 +02:00
Konstantinos Karmas
3e143a012a Change the setting version to 19
Since the setting version 18 is used in the arachne beta build, we decided to make the the setting version to 19 in the normal releases, so that we make sure that projects made in arachne beta won't use any version upgrade scripts if a user attempts to open them in 4.12.

CURA-8510
2021-09-15 16:25:04 +02:00
THeijmans
0152a0429a Updates acceleration settings to a max of 3500mmps2
And increases minimum to 1000mmps2.
2021-09-15 14:32:39 +02:00
THeijmans
6a4f59c27a Updates Jerk settings to a minimum of 20mmps
For PP-1
2021-09-15 12:59:00 +02:00
Ghostkeeper
453b666b1d
Increment setting_version to 18
We now have version 18, where Flsun Super Racer has customised profiles.
Nothing changes in the built-in profiles. It only needs a change in the machine instances.

Contributes to issue CURA-8510.
2021-09-14 16:32:43 +02:00
Kostas Karmas
2645dc880e Update setting version to 17 for 4.10
CURA-8212
2021-05-10 17:39:33 +02:00
Kostas Karmas
5bca31e37a Update setting version to 18 for libArachne release
Although it is not entirely sure yet, we are fairly certain that libArachne release will have
a setting version of 18, so it is changed by this commit. With this change, the VersionUpgrader
will be properly triggered.

Contributes to CURA-7683 and CURA-7656
2020-12-02 15:29:25 +01:00
Ghostkeeper
a7b2f7de5a
Upgrade setting_version to 16
We have a change now that requires a version upgrade. This triggers all profiles to update for the user, and we must update accordingly in the built-in profiles.

Contributes to issue CURA-7118.
2020-09-02 01:51:13 +02:00
Ghostkeeper
9d178f26a7
Increment setting version to 15
Once more into the fray.

Contributes to issue CURA-7420.
2020-05-08 09:43:02 +02:00
Kostas Karmas
9bf0255046 Up the setting version to 14 in all the resourses
CURA-7421
2020-05-04 13:13:07 +02:00
Ghostkeeper
e2e69f6646
Increment setting version to 13
Contributes to issue CURA-7282.
2020-04-01 15:14:01 +02:00
Ghostkeeper
8422172000
Increment setting version to 12
This is necessary for the version upgrade to run.

Contributes to issue CURA-7328.
2020-03-30 11:54:18 +02:00
Ghostkeeper
fdd1cef11a
Reduce stair step height to 0 for PVA
Given that:
* stair stepping is intended to be used to reduce the adhesion between support and the model, where the support rests on the model, and to reduce scarring, and
* PVA doesn't suffer from scarring or adhesion issues due to its water-solubility, and
* our current stair stepping algorithm has some bugs, causing support to disappear sometimes

we've decided to set stair stepping to 0 for all PVA profiles for UM3, UMS5 and UMS3.

Contributes to issue CURA-7311.
2020-03-18 15:50:27 +01:00
Dimitriovski
94a5b5ef90 CURA-6522_one_at_a_time_overlapping_build_area
Changed the setting_version to 11
2019-11-19 15:27:17 +01:00
Lipu Fei
1977a865f1 Fix HMS434 version upgrade
CURA-6774
2019-09-24 11:05:52 +02:00
Jaime van Kessel
e56e355e79 Added upgrader for 4.3 2019-07-23 11:15:13 +02:00
Ghostkeeper
a38984dcec
Increment setting_version to 8
This is required for the version upgrade.

Contributes to issue CURA-6311.
2019-06-12 09:09:41 +02:00
Lipu Fei
2aa985c6de Update all profiles to setting_version 7
CURA-6113
2019-01-17 11:49:26 +01:00
Ghostkeeper
139ab2e0bb
Increment setting_version to 6
Because Cura 4.1 is going to have a version upgrade to change the stack files.

Contributes to issue CURA-5848.
2018-12-27 16:39:05 +01:00
DavidGergely
ea8d10783c Cura-5457 prime tower settings
New settings for the prime towers for all profiles expect PP0.8 printcore
2018-08-03 14:12:36 +02:00
Ghostkeeper
ec00e5b721
Remove references to deleted settings
Also convert the values for prime_tower_min_volume to make it behave similar to what the minimum volume used to be. This feature fixed a bug with the computation from volume to thickness. Now it's correct but we have to correct the old values to be still the same (approximately) as what used to be the end result.

Contributes to issue CURA-5457.
2018-07-05 13:22:17 +02:00
Lipu Fei
b81635ac8e Update setting_version to 5 and add 34 -> 40 upgrade
CURA-5450

Also update setting_version for all qualities and variants.
2018-06-12 10:17:35 +02:00
Lipu Fei
9a5fb47a6e Merge master into material marketplace 2018-05-01 11:56:34 +02:00
Lipu Fei
ed390738f4 Update all qualities and variants to version 4 2018-04-05 15:14:15 +02:00
THeijmans
dbd25d1d53 PVA prime tower update
Updated PVA prime towers for more reliability
2018-03-20 15:59:25 +01:00